The Siemens SIMATIC S7-1500 CPU 1517-3 PN/DP (6ES7517-3AP00-0AB0) is a high-performance central processing unit designed for demanding industrial automation, machine control and manufacturing applications. As a member of the Siemens SIMATIC S7-1500 PLC family, this controller combines fast processing, substantial work memory and multiple industrial communication interfaces to support complex automation systems.
With 2 MB of work memory for programs and 8 MB for data, the CPU provides resources for sophisticated control logic, data processing, communication and system integration. It features three communication interfaces: PROFINET IRT with an integrated two-port switch, a second PROFINET RT interface, and a PROFIBUS interface. These interfaces support integration with compatible PLC devices, remote I/O systems, HMIs, drives and other industrial automation equipment.
The CPU is engineered for applications requiring dependable control, fast response and flexible communication between automation components. It can be used in manufacturing facilities, automated machinery, production lines and industrial process-control systems where the S7-1500 platform is appropriate.
Manufacturer: Siemens
Product family: SIMATIC S7-1500
Product type: CPU 1517-3 PN/DP
Order number: 6ES7517-3AP00-0AB0
Controller category: Standard PLC CPU
Program work memory: 2 MB
Data work memory: 8 MB
First interface: PROFINET IRT with integrated two-port switch
Second interface: PROFINET RT
Third interface: PROFIBUS
Typical bit operation time: 2 ns
Rated supply voltage: 24 V DC
Permissible supply voltage: 19.2–28.8 V DC
Memory card: SIMATIC Memory Card required
Maximum supported memory card capacity: 32 GB, subject to Siemens compatibility requirements
Engineering software: STEP 7 in TIA Portal, with the appropriate version and firmware support
The CPU 1517-3 PN/DP is designed for automation projects that require substantial processing capability and memory resources. Its 2 MB program work memory and 8 MB data work memory support control programs, process data and application logic suitable for complex industrial installations.
The specified typical bit operation time of 2 ns makes this CPU suitable for applications where rapid execution of control instructions is important. Actual system performance depends on the program, hardware configuration, communication load and application requirements.
The first integrated interface supports PROFINET IRT and includes a two-port switch. This helps connect compatible industrial devices in a PROFINET network and can simplify wiring in supported network configurations.
The interface can be used for communication with compatible distributed I/O, operator panels, drives and other automation devices. Network design should follow Siemens' recommendations and the requirements of the connected equipment.
A second PROFINET RT interface provides additional options for connecting compatible devices and organizing industrial Ethernet communication. Depending on the application design, the separate interfaces can help structure communication between automation components and connected networks.
Confirm the intended network topology, addressing, communication requirements and supported configuration before commissioning.
The third interface supports PROFIBUS communication, helping integrate compatible PROFIBUS devices into an automation system. This can be particularly useful when maintaining or upgrading installations that contain existing PROFIBUS-based equipment.
Compatibility depends on the connected device, bus configuration, required communication functions and system engineering.
The CPU is configured and programmed using Siemens STEP 7 engineering software in TIA Portal. The correct software version depends on the CPU firmware and the project requirements. Siemens documentation lists support from specific TIA Portal versions, with newer firmware requiring newer engineering software.
Before programming or replacing a CPU, verify the hardware version, firmware, project compatibility and engineering software requirements.
A compatible SIMATIC Memory Card is required for this CPU. The memory card is used for load memory and related operating requirements. Confirm whether a memory card is included in the product offer before purchasing, as included accessories may vary.
The Siemens CPU 1517-3 PN/DP may be used in suitable applications such as:
Factory and manufacturing automation
Automated production lines
Packaging and filling machinery
Conveyor and material-handling systems
Textile and garment machinery
Food and beverage processing equipment
Water treatment and utility automation
Industrial pump and compressor control
Machine-building and OEM automation projects
Remote I/O and distributed automation systems
Industrial Ethernet and PROFIBUS integration
Existing Siemens S7-1500 system maintenance and expansion
The suitability of the CPU for a particular application depends on the required processing capacity, communication architecture, supported technology functions and overall system design.
| Specification | Details |
|---|---|
| Manufacturer | Siemens |
| Product series | SIMATIC S7-1500 |
| CPU model | CPU 1517-3 PN/DP |
| Part number | 6ES7517-3AP00-0AB0 |
| Program work memory | 2 MB |
| Data work memory | 8 MB |
| Interface 1 | PROFINET IRT with two-port switch |
| Interface 2 | PROFINET RT |
| Interface 3 | PROFIBUS |
| Typical bit operation time | 2 ns |
| Supply voltage | 24 V DC |
| Permissible voltage range | 19.2–28.8 V DC |
| Memory card requirement | SIMATIC Memory Card required |
| Maximum memory card capacity | 32 GB |
| Programming environment | Siemens STEP 7 / TIA Portal |
PLC Mart BD supports customers looking for Siemens PLCs and industrial automation components for new installations, replacement projects and maintenance requirements. Providing the complete Siemens order number helps identify the correct product version and reduces the risk of ordering an incompatible component.
When enquiring about the Siemens CPU 1517-3 PN/DP, use the exact part number 6ES7517-3AP00-0AB0. Confirm product availability, condition, warranty, included accessories and delivery arrangements before placing an order.
Confirm the exact part number before purchasing.
Check hardware and firmware compatibility with your existing S7-1500 system.
Verify the required TIA Portal version for your project.
Ensure that a compatible SIMATIC Memory Card is available.
Confirm the required PROFINET and PROFIBUS communication capabilities.
For replacement projects, review the existing PLC configuration and program compatibility before installation.
Product Summary: The Siemens SIMATIC S7-1500 CPU 1517-3 PN/DP, part number 6ES7517-3AP00-0AB0, is a standard industrial PLC CPU with 2 MB program work memory, 8 MB data work memory, PROFINET IRT, PROFINET RT and PROFIBUS communication interfaces. A SIMATIC Memory Card is required.
Login Or Registerto submit your questions to seller
No none asked to seller yet